All requests are made using HTTP GET and are case sensitive. Each subheading below should be passed to your device as follows:

curl http://192.168.XXX.XXX/heaterName.cgi`

All inputs are also passed via standard HTTP GET arguments as follows:

curl http://192.168.XXX.XXX/ctrl.cgi?sid=0&heatingCtrl=1

All responses are provided in JSON.

DDoS protection

Note: This information is based on speculation, the author has not seen the underlying code to confirm whether or not it is correct.

My Rheem water heater has some basic DDoS protection which was causing lots of connectivity issues which I had thought was due to the devices being around 10 metres apart and seperated by a wall and (including a metal door) - which I thought was reducing signal strength.

Essentially, if the device receives more than 1 request per second (the author cannot determine the precise limits of this), the device will enter a state whereby it will refuse all connections. Since updating to the new Home Assistant logic provided here I haven't run into this issue for around 3 weeks (it previously occurred almost daily especially when there would tend to be a lot of radio interference).

Continued requests (again the author cannot state what this limit is) will cause the device to lock itself down and refuse to answer any requests until the water heater is physically switched on and off again.

/heaterName.cgi

Example output:

{"heaterName":"Rheem"}

Inputs:

None

Outputs:

Name Type Description
heaterName string The friendly name of your heater unit.

/version.cgi

Example output:

{"FWversion":"1.4"}

Inputs:

None

Outputs:

Name Type Description
FWversion string The firmware version of your control unit.

/getParams.cgi

Example output:

{"heaterModel":1,"tempMax":50,"tempMin":37,"bathtempMax":48,"bathtempMin":37,"bathvolMax":500,"bathvolMin":10}

Inputs:

None

Outputs:

Name Type Description
heaterModel integer Unknown for now. My unit responds with 1. Further research is required to enumerate the model numbers.
tempMax integer The maximum temperature that the hot water supply can provide.
tempMin integer The minimum temperature that the hot water supply can provide.
bathtempMax integer The maximum temperature that the hot water can supply for Bath Fill mode. This mode is designed (as the name implies) to supply a large fixed volume of water at once for filling baths. After the volume is supplied, the water supply will turn itself off.
bathtempMin integer The minimum temmperature for Bath Fill mode (see above).
bathvolMax integer The maximum volume of water to supply for Bath Fill mode (see above).
bathvolMin integer The minimum volume of water to supply for Bath Fill mode (see above).

/getInfo.cgi

Example output:

{"heaterName":"Rheem","mode":10,"temp":37,"flow":0.0,"wtemp":14.1,"intemp":17.9,"state":1,"appErrCode":0,"sid":1154,"sessionTimer":300,"sTimeout":248,"heatingCtrl":1,"bathfillCtrl":0}

Inputs:

Name Required Type Description
sid false integer A session id from /ctrl.cgi. If session id is provided then the extra outputs below are revealed.

Outputs:

Name sid Required Type Description
heaterName false string The friendly name of your heater unit.
mode false integer See below table.
temp false integer The requested hot water temperature
flow false float The current flow of hot water through the unit in L/ min rounded to 1 decimal place.
state false integer 1 = idle, 2 = water heater active, 3 = valve closed after bath fill
appErrCode false integer Apparently, an error code output - codes unknown for now.
sTimeout false integer If a user has control of the water heater, returns the time left until that session expires in seconds. Otherwise, returns 0.
sessionTimer false integer Returns the configured session timeout for a user in seconds.
bathtemp false integer If bath fill mode is activated, returns the requested bath fill temperature.
bathvol false integer If bath fill mode is activated, returns the requested bath fill volume.
fillPercent false float If bath fill mode is activated, returns approximate percentage of bath volume dispensed (this percentage is not accurate for very small bath fill volumes).
wtemp true float The current water temperature as read from the heating block of the water heater in degrees celcius rounded to 1 decimal place.
intemp true float The current intake water temperature from supply in degrees celcius rounded to 1 decimal place.
sid true integer Returns your current session id.
heatingCtrl true integer Returns 1 if you currently have control of the water heater using conventional mode. Otherwise returns 0.
bathfillCtrl true integer Returns 1 if you currently have control of th water heater using bath fill mode. Otherwise returns 0.

Modes:

Value Description
5 Idle
10 Heating Control Mode
15 Water Heater Active (Conventional Mode)
20 Bath Fill Active (Waiting for Tap Open)
25 Water Heater Active (Bath Fill Mode)
35 Bath Fill Complete (Water Flow Disabled)

/ctrl.cgi Conventional

Example output:

{"sid":463,"sTimeout":300,"heatingCtrl":1,"bathfillCtrl":0}

Inputs:

Name Required Type Description
sid false integer A session id from /ctrl.cgi. A session id of 0 must be provided to take control of the water heater.
heatingCtrl false integer 1 = Take control, 0 = Relinquish control

Outputs:

Name sid Required Type Description
sid false integer Returns your sid, if you have control. Otherwise, returns 0.
sTimeout false integer If a user has control of the water heater, returns the time left until that session expires in seconds. Otherwise, returns 0.
heatingCtrl true 1 = Your session has control, 0 = Your session does not have control.
bathfillCtrl true integer See Bath Fill Mode below.

/ctrl.cgi Bath Fill Mode

Example output:

{"sid":649,"sTimeout":60,"heatingCtrl":0,"bathfillCtrl":1,"reqbathtemp":37,"reqbathvol":10}

Inputs:

Name Required Type Description
sid true integer A session id from /ctrl.cgi. A session id of 0 must be provided to take control of the water heater.
bathfillCtrl true integer 1 = Take control, 0 = Relinquish control
setBathTemp false integer (Required if batthfillCtrl=1) A requested temperature for the bath fill in degrees celcius.
setBathVol false integer (Required if batthfillCtrl=1) A requested volume for the bath fill in litres of water.

Outputs:

Name sid Required Type Description
sid false integer Returns your sid, if you have control. Otherwise, returns 0.
sTimeout false integer If a user has control of the water heater, returns the time left until that session expires in seconds. Otherwise, returns 0.
heatingCtrl true 1 = Your session has control, 0 = Your session does not have control.
bathfillCtrl true integer 1 = Your session has control, 0 = Your session does not have control.
reqbathtemp true integer Returns your requested bath fill temperature in degrees celcius.
reqbathvol true integer Returns your requested bath fill volume in litres.

/set.cgi

These commands require that you have control via /ctrl.cgi and a session id. At least one of the command inputs must be provided.

Inputs:

Name Required Type Description
sid true integer A session id from /ctrl.cgi.
setTemp false integer Sets the requested hot water temperature in degrees celcius. You can reduce the temperature while water is flowing and you can also increase the temperature to a maximum of 43C (if you take control before turning on the water).
setSessionTimer false integer Sets the session timer in seconds after which your control of the water heater will automatically timeout and allow other users control.

Outputs - setTemp:

Name Type Description
temp integer Returns the previously set temperature
reqtemp integer Returns your requested temperature
sid integer Returns your session id
sTimeout integer Returns your timeout.

Outputs - setSessionTimer

Name Type Description
SessionTimer integer Returns your requested session timer